Get in touch
555-555-5555
mymail@mailservice.com

Industrial I/O and Automation > OPC UA Solutions

OPC UA

Quick Guide to OPC UA and Advantech IT/OT Convergent Solutions

OPC UA, which stands for Open Platform Communications Unified Architecture, is a single service oriented architecture that provides everything needed for the transport and interpretation of data and information from first-tier control devices through to the enterprise information systems.

Learn why OPC UA is an accelerator for Industry 4.0 and the industrial internet of things, and learn where the technology is likely to lead in the future.

OPC UA- More Than Just Another Protocol

In this video, you will quickly learn how OPC UA benefits your business.

  • Who are the OPC Foundation and what do they do
  • Why OPC UA is more than ‘just another protocol’, and how it enables IT-OT convergence
  • How to integrate legacy devices into an OPC UA framework


Featured Speakers


Stefan Hoppe 

President and Executive Director,

OPC Foundation

Tim Taberner

Technical Sales Director,

Advantech IIoT Europe

Quick Guide to OPC UA- 12 FAQs

What customer challenges does OPC UA address?

OPC UA provides a unified architecture and lexicon to define field items, the devices that interface to them and the communications between them. It enables the free flow of information between systems in a manner that allows not only the data, but also the source of the data to be defined and understood. It achieves this in an extremely secure way, providing high levels of trust and resilience in the retrieved information. As such it is highly relevant to customers:


  • Seeking to integrate information from diverse device types into a complete system
  • Optimizing end-to-end operations rather than individual, discrete processes
  • Trying to bridge the divide between IT and OT environments


What is OPC UA and what does OPC UA stand for?

OPC is an acronym for Open Platform Communications. A number of interoperability specifications have been released over the years and in its latest iteration, OPC UA (Open Platform Communications Unified Architecture) integrates all this functionality into a single service oriented architecture. At the same time, it adds essential new features such as platform independence, diagnostics, discovery, rendering of complex information models, security, and reliability. It also provides everything needed for the transmission and interpretation of data and information from the factory or enterprise information system. OPC UA was released as an IEC Standard, IEC 62541 in October 2011.

 

Why is OPC UA important?

The OPC UA standard brings plug-and-play connectivity to industrial automation. Before OPC UA, application vendors had to develop custom software for every third-party device and application that needed to be integrated into the automation system. OPC UA instead offers open connectivity across products, independent of the hardware or software platforms involved. OPC UA defines a standard way for sharing real-time data, historical data, and alarms & events, reducing integration and total life cycle cost for system implementation.

 

What are the benefits of OPC UA?

  • Object definition library provides contextualized information, not raw data, which enables true interoperability ‘out of the box’ across multiple vendors and device/applications
  • Standardized information enables efficient asset performance management
  • Open ecosystem avoids vendor lock-in
  • Vendors differentiate by additional features and quality; not by proprietary restrictions
  • End to end security model allows use across multiple communications networks
  • Specifications, sample code etc. are all openly and freely available. No royalties to pay on any runtimes. Membership of the OPC Foundation is not necessary to access resources or certification labs. Modern IPR policy protects not only OPC foundation members, but also all adopters of OPC UA
  • Companion specifications can be developed for devices and IT applications and services, providing a single architecture within which both OT and IT systems can interact in a common manner

How is OPC UA different from other protocols such as DDS, AMQP or MQTT?

The first thing to understand is that OPC UA is more than just a protocol. Protocols such as DDS, AMQP or MQTT are concerned with the transfer of data between applications, devices and systems. They achieve this with different levels of intrinsic security, but they do not implicitly provide any context for the data being transferred. Instead, it is up to the user to define the content of the data and because of this, it does not guarantee that the transferred data can be interpreted by a receiving system. 



OPC UA addresses this by including definitions not only of data and information types, but also of the device or application which generated the data using a common object definition library (OPC UA refers to these as ‘companion specifications’). Because of this, any system implementing the OPC UA architecture is guaranteed to be able to natively connect to and interpret data from any device which supports the same companion specs.

 

In addition to this common object library, OPC UA also addresses security from an end-to-end perspective. As such it can be used with multiple transfer protocols including both client-server and pub-sub protocols like MQTT whilst maintaining data and user security independently of the transport layer.

 

How does OPC UA drive industry 4.0?

For industry 4.0 to be fully realized, there are several key issues that must be addressed, namely security, interoperability, real time operation and IT-OT integration. OPC UA provides features which address each of these requirements within a single unified architecture model:


  • Security

OPC UA provides end to end security, starting with a hardware root of trust within devices, and extending through the transport, application and user security levels. All devices within a system are authenticated, and all communications are signed and encrypted.

  • Interoperability

OPC UA provides definitions not only of data fields and types, but also how combinations of those data fields are joined into an object which models a real device. Sharing these object definitions allows authorized OPC UA applications and devices to not only recover data, but also to interpret it without human intervention. Devices conforming to an OPC UA companion specification, for example ‘a robot’ can be freely mixed and matched within a system irrespective of manufacturer or specific characteristics such as degrees of freedom etc.

  • Real Time Operation

In addition to offering pub-sub transport layers for rapid one-to-many communications in large systems, OPC UA is able to leverage deterministic networks using Time-Sensitive Networking (TSN).

  • IT-OT Integration

Companion specifications can be used to define applications and services available within IT systems, allowing their integration within a unified OPC UA architecture in exactly the same way as real word devices are modelled and accessed.


How does OPC UA do vs. other industry standards regarding cost/revenue?

Specifications, sample code etc. are all openly and freely available. No royalties to pay on any runtimes. Membership of the OPC Foundation is not necessary to access resources or certification labs. A modern IPR policy protects not only OPC foundation members, but also all adopters of OPC UA.

 

There is a level of complexity within OPC UA which means there appears to be a steeper learning curve than for some other technologies. In reality this is rarely the case because of the comprehensive nature of the specification. With other technologies users must factor in the learning curves of associated technologies needed in order to build a complete, end to end, secure, resilient, interoperable and open system. Once all of these parallel learning curves are considered, it can be seen that OPC UA is not any more complex or expensive to implement than any other system offering similar capabilities. Indeed, because features are already integrated into the specification, the overall effort required to implement an OPC UA based system can be considerably less than with other approaches.


What are OPC UA’s major applications?

OPC has its origins in the OT layer between smart devices such as PLCs and supervisory systems such as SCADA. Whilst OPC UA remains highly relevant in this area, the object based nature of the architecture mean that the real hotspot is in the interface to SOA based IT systems, which really benefit from the ability to group and define data by asset type, and the richness of the datasets it provides against these asset models.

At the same time, OPC UA is significantly improving the ability for factory floor systems to communicate with each other in a peer-to-peer arrangement. This can significantly increase the efficiency of a production line by eliminating the delays associated with handing production process between machines, whilst also allowing machines that have otherwise incompatible fieldbus or protocol models to interact directly with each other.

How widely adopted is OPC UA?

There are over 450 companies who are members of the OPC foundation. Hundreds more are developers or users of OPC technologies without being foundation members. Users come from OT, IT, academic and research backgrounds, and range from small independent software provides to large multi-national automation corporations. Collaboration groups exist to share resources, knowledge, and promote the OPC UA architecture and its related companion specifications.


What are the benefits of OPC UA Ethernet I/O vs. Modbus Ethernet I/O?

OPC UA Ethernet I/O provides a much richer datastream which allows its direct use in applications without prior knowledge. Modbus (P1 port) Ethernet I/O is compatible with older SCADA systems, but simply provides a stream of ‘1’ and ‘0’s, leaving the user to define and configure all of the information which contextualizes it. With Advantech OPC UA Ethernet I/O, you’re covered either way, as they provide support for both OPC UA and Modbus TCP.


How OPC UA enables and simplifies remote facility management?

Let’s start by analyzing the ideal needs of any system targeting remote management. Firstly it must be secure, to ensure that only authorized actors can interact with each other, and can see the data flowing between them. Secondly, it must have the versatility to work over a number of different communication topologies, including some which are subject to occasional dropout. Then, it needs to work with not just a single type of device from a single vendor, but instead with multiple device types from multiple vendors. It also needs to provide an easy way to contextualize the data that is flowing, ideally one which is machine readable rather than requiring human intervention of interpretation. Finally, it needs to interact with multiple systems, both from an IT and OT background. Of course, it is possible to address all of these elements by combining and integrating technology solutions from multiple sources, but OPC UA provides all of this within a single, open and publicly adopted standard. Simply by deciding to base a system architecture on OPC UA, all of these elements are intrinsically available ‘out of the box’, leaving users to concentrate on their application and value add, rather than the mechanics of building an infrastructure.


Why Advantech WISE-EdgeLink software is the optimal protocol gateway solution for OPC UA

applications?

Innovation in the industrial automation industry is often limited by the installed base of monitoring and control devices at the edge. Product lifecycles in the industry mean that these can often be ten or fifteen years old, relying on communication technologies and protocols prevalent at the time of installation. It is often impractical to replace all of these legacy assets when wanting to adopt new technologies. Advantech WISE-EdgeLink software provides the necessary bridge between them and modern systems based upon standards such as OPC UA, enabling users to migrate to take advantage of new innovations whilst protecting your investment.


Contact Our Experts

Advantech OPC UA Applications

An OPC UA Solution for Wastewater Treatment Monitoring System

Wastewater treatment requires an automated monitoring system to ensure that each and every one of the equipment units is operating in good standing and protects workers from exposure to pollutants or harmful chemicals. Advantech has been an important supplier for data acquisition modules and other products needed for building an intelligent SCADA system in many sewage treatment projects around the world. Our newest solutions supporting OPC UA will help reduce the cost of maintaining an IoT network and enhance data security from the field to the cloud.

 

ADAM-6300 : OPC UA remote I/O module

ICR-2431 : 4G/LTE cellular router

ICR-4453 : 5G router & gateway

ADAM-3600 : all-in-one intelligent RTU

MIC-710 : AI edge computer

WISE-EdgeLink : communication gateway software

View More

OPC UA Enabled SCADA Monitoring Solution for Gas Stations

The operation of a gas stations involves a lot of automation and sensors for filling different vehicles with fuel. Any leaks of fuel into the air or the soil would not only undermine revenues but could also harm the environment and the health of workers at the station. Advantech’s ecosystem partner in the Middle East used our ADAM data acquisition I/O modules and an all-in-one intelligent remote terminal unit (iRTU) supporting OPC UA to realize a cost effective SCADA monitoring solution that delivered unparalleled data security.


ADAM-3600 : all-in-one intelligent RTU

ADAM-4000 : serial I/O module 

ADAM-6200 : Ethernet I/O module 

UNO-410 : explosion-proof computer

WISE-EdgeLink : communication gateway software 

View More

Advantech OPC UA Product Offerings

OPC UA Remote I/O

ADAM-6300

Buy Now Online Learning

OPC UA I/O Gateway

ADAM-6700 WISE-EdgeLink

View More Online Learning

OPC UA I/O Gateway & RTU

ESRP-PCS-ADAM3600

Buy Now Online Learning

OPC UA Lightweight Gateway

ESRP-PCS-ECU1051

View More Online Learning

OPC UA
Lightweight Gateway

ESRP-PCS-ECU1251

Buy Now Online Learning

Modbus to OPC UA
Fieldbus Gateway

EKI-1242IOUMS

View More Online Learning

OPC UA
Edge Gateway

ESRP-PCS-ECU4553

View More

OPC UA CODESYS Controller &
Fieldbus Gateway

AMAX-658

View More

OPC UA CODESYS Controller &
Fieldbus Gateway

AMAX-637

View More

OPC UA
Edge Gateway

ESRP-CSS-UNO2271

Buy Now View More

OPC UA

Edge Gateway

ESRP-CSS-UNO2484

Buy Now View More

OPC UA

Edge Gateway

ESRP-CSS-UNO2372

Buy Now View More

OPC UA
Edge Gateway

ESRP-CSS-UNO1372

Buy Now View More

OPC UA
Edge Gateway

ESRP-CSS-UNO137

View More

OPC UA

Edge Gateway

ESRP-PCS-UNO420

View More

OPC UA Product Specifications

OPC UA Products ADAM-6300 ESRP-PCS-ADAM6700 ESRP-PCS-ADAM3600 ESRP-PCS-ECU1051 ESRP-PCS-ECU1251 EKI-1242IOUMS ESRP-PCS-ECU4553 AMAX- 658 AMAX-637 ESRP-CSS-UNO2271 ESRP-CSS-UNO2484 ESRP-CSS-UNO2372 ESRP-CSS-UNO1372 ESRP-CSS-UNO137 ESRP-PCS-UNO420
Product Types Remote I/O Modules I/O Gateway I/O Gateways & RTU Lightweight Gateway Lightweight Gateway Modbus to OPC UA Fieldbus Gateway Edge Gateway Codesys Controller & Fieldbus Gateway Codesys Controller & Fieldbus Gateway Edge Gateway Edge Gateway Edge Gateway Edge Gateway Edge Gateway Edge Gateway
OPC UA Server Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
OPC UA Client Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
I/O Modules Yes Yes Yes Yes Yes
Hardware MCU ARM ARM ARM ARM ARM ARM X86 X86 X86 X86 X86 X86 X86 X86
Operating System non-OS Embedded Linux Embedded Linux Embedded Linux Embedded Linux Embedded Linux Embedded Linux Windows Windows Linux Linux Linux Linux Linux Linux
Industrial Connectivity OPC UA, Modbus/TCP Modbus, BACNet, IEC-101, IEC-104 Modbus, BACNet, DNP3, IEC-101, IEC-104 Modbus, BACNet, DNP3, IEC-101, IEC-104 Modbus, BACNet, DNP3, IEC-101, IEC-104 Modbus Modbus, BACNet, DNP3, IEC-101, IEC-104 EtherCAT, PROFINET, EtherNet/IP, Modbus, Profibus, CANOpen EtherCAT, PROFINET, EtherNet/IP, Modbus, Profibus, CANOpen Modbus Modbus Modbus Modbus Modbus Modbus
Network Connectivity LAN LAN LAN, WiFi, Cellular LAN/WIFI/Cellular LAN, WiFi, Cellular LAN LAN LAN LAN LAN, WiFi, Cellular LAN, WiFi, Cellular LAN, WiFi, Cellular LAN, WiFi, Cellular LAN, WiFi, Cellular LAN, WiFi, Cellular
Form Factor Wall mount, DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail Rack mount DIN Rail DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail Wall mount, DIN Rail DIN Rail DIN Rail Wall mount
Codesys Yes Yes
Edgelink Yes Yes Yes Yes Yes Yes - - Yes Yes Yes Yes Yes Yes
Cloud Services Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT MQTT (Sparkplug), ODBC MQTT (Sparkplug), ODBC Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT Azure, AWS, MQTT
Contact Our Experts

Resources Download


Introduction to OPC UA- More
Than Just Another Protocol


Download

Advantech OPC UA Solutions
Sales Kit



Download

Advantech OPC UA I/O Modules: ADAM-6300 Product Leaflet


Download

Contact Us

Advantech Newsletter

Sign up for the latest industrial I/O, automation and intelligent connectivity product and event updates,

industry news, case studies, and more from Advantech.

Subscribe Now

Follow Advantech

How Can We Help?

Share by: